Skip to Content
RTP Scientific Supply
RTP Scientific Supply
Analytical instrument
General lab equipment
Lab Accessories
Request/Contact
About
Login Account
(0)
Cart (0)
RTP Scientific Supply
RTP Scientific Supply
Analytical instrument
General lab equipment
Lab Accessories
Request/Contact
About
Login Account
(0)
Cart (0)
Analytical instrument
General lab equipment
Lab Accessories
Request/Contact
About
Login Account
General lab equipement Milli-Q IQ 7000 Ultrapure Water Purification System with Q-POD, 90 Day Warranty
IMG_2355.jpeg Image 1 of 9
IMG_2355.jpeg
IMG_2360.jpeg Image 2 of 9
IMG_2360.jpeg
IMG_2363.jpeg Image 3 of 9
IMG_2363.jpeg
IMG_2365.jpeg Image 4 of 9
IMG_2365.jpeg
IMG_2366.jpeg Image 5 of 9
IMG_2366.jpeg
IMG_2421.png Image 6 of 9
IMG_2421.png
IMG_2427.png Image 7 of 9
IMG_2427.png
IMG_2355.jpeg Image 8 of 9
IMG_2355.jpeg
IMG_2359.jpeg Image 9 of 9
IMG_2359.jpeg
IMG_2355.jpeg
IMG_2360.jpeg
IMG_2363.jpeg
IMG_2365.jpeg
IMG_2366.jpeg
IMG_2421.png
IMG_2427.png
IMG_2355.jpeg
IMG_2359.jpeg

Milli-Q IQ 7000 Ultrapure Water Purification System with Q-POD, 90 Day Warranty

$8,900.00

Simple & Intuitive Dispensing

Dispensing ultrapure water from the Q-POD® has become much easier, precise and effortless with the new “wheel” dispense. You can access a large number of dispensing functions that are useful for day-to-day work in the laboratory.

Large, Interactive Touch Screen

Like a smartphone, the Q-POD® dispenser's interactive touch screen allows you to go anywhere in just a few clicks.

Optimized Lab Space

Protect your working space from clutter! The system is designed for a neat installation and clean lab benches, free of loose tubing and cables. Just interact with your Q-POD® dispenser — the rest of the compact system can easily be integrated in the lab environment. For labs needing more than one ultrapure water point-of-use, up to four Q-POD® dispensers can be connected.

Superior Ultrapure Water — Consistently — to the Trace Level

The Milli-Q® IQ 7000 system provides superior ultrapure water consistently to the trace level with the combination of Jetpore® and IQnano™ resin. Plus, tailored media optimizes performance as purification cartridges can be adapted to your feed water situation, whether extra hard tap water, or Elix® or non-Elix® pure water feed. You can fully rely on the system's water purity for your critical experiments. And with the A10® TOC on-board monitoring, you're spared from uncertainty or misinterpreting results — and also from having to repeat time-consuming and costly analyses.

Water Specifications / International Conformity

Feed water requirements

Feed water quality Pretreated water using EDI, DI, RO or distillation technologies

Conductivity at 25 °C < 100 µS/cm (as NaCl)

Total Organic Carbon (TOC) < 50 ppb

Pressure range* Max 6 bar

Temperature 5 – 35 °C / 41 – 95 °F

* For pressures between 0 and 0.1 bar, the system will operate, but product flow rate may be lower.

Ultrapure, Type 1 water specifications1 (from Q-POD® dispenser)

Resistivity at 25 °C2 18. 2 MΩ·cm

TOC3 ≤ 2 ppb (μg/L)(3), typically ≤ 5 ppb (μg/L)

Particles4 No particles with size > 0.22 µm

Bacteria <0.01 cfu/mL (<10 cfu/L)(4,5)
<0.005 cfu/mL (<5 cfu/L)(6)
Pyrogens (endotoxins)5 < 0.001 EU/mL

RNases5 < 1 pg/mL

DNases5 < 5 pg/mL

Proteases5 < 0.15 µg/mL

Flow rate 0.05 – 2 L/min

1 These values are typical and may vary depending on the nature and concentration of contaminants in the feed water.
2 Resistivity can also be displayed non-temperature-compensated as required by USP.
3 In the appropriate operating conditions, otherwise typically ≤ 5ppb.
4 With Millipak® and Millipak® Gold
5 With Biopak®
6 With Millipak® Gold installed and used in a laminar flow hood

Add To Cart

Simple & Intuitive Dispensing

Dispensing ultrapure water from the Q-POD® has become much easier, precise and effortless with the new “wheel” dispense. You can access a large number of dispensing functions that are useful for day-to-day work in the laboratory.

Large, Interactive Touch Screen

Like a smartphone, the Q-POD® dispenser's interactive touch screen allows you to go anywhere in just a few clicks.

Optimized Lab Space

Protect your working space from clutter! The system is designed for a neat installation and clean lab benches, free of loose tubing and cables. Just interact with your Q-POD® dispenser — the rest of the compact system can easily be integrated in the lab environment. For labs needing more than one ultrapure water point-of-use, up to four Q-POD® dispensers can be connected.

Superior Ultrapure Water — Consistently — to the Trace Level

The Milli-Q® IQ 7000 system provides superior ultrapure water consistently to the trace level with the combination of Jetpore® and IQnano™ resin. Plus, tailored media optimizes performance as purification cartridges can be adapted to your feed water situation, whether extra hard tap water, or Elix® or non-Elix® pure water feed. You can fully rely on the system's water purity for your critical experiments. And with the A10® TOC on-board monitoring, you're spared from uncertainty or misinterpreting results — and also from having to repeat time-consuming and costly analyses.

Water Specifications / International Conformity

Feed water requirements

Feed water quality Pretreated water using EDI, DI, RO or distillation technologies

Conductivity at 25 °C < 100 µS/cm (as NaCl)

Total Organic Carbon (TOC) < 50 ppb

Pressure range* Max 6 bar

Temperature 5 – 35 °C / 41 – 95 °F

* For pressures between 0 and 0.1 bar, the system will operate, but product flow rate may be lower.

Ultrapure, Type 1 water specifications1 (from Q-POD® dispenser)

Resistivity at 25 °C2 18. 2 MΩ·cm

TOC3 ≤ 2 ppb (μg/L)(3), typically ≤ 5 ppb (μg/L)

Particles4 No particles with size > 0.22 µm

Bacteria <0.01 cfu/mL (<10 cfu/L)(4,5)
<0.005 cfu/mL (<5 cfu/L)(6)
Pyrogens (endotoxins)5 < 0.001 EU/mL

RNases5 < 1 pg/mL

DNases5 < 5 pg/mL

Proteases5 < 0.15 µg/mL

Flow rate 0.05 – 2 L/min

1 These values are typical and may vary depending on the nature and concentration of contaminants in the feed water.
2 Resistivity can also be displayed non-temperature-compensated as required by USP.
3 In the appropriate operating conditions, otherwise typically ≤ 5ppb.
4 With Millipak® and Millipak® Gold
5 With Biopak®
6 With Millipak® Gold installed and used in a laminar flow hood

Simple & Intuitive Dispensing

Dispensing ultrapure water from the Q-POD® has become much easier, precise and effortless with the new “wheel” dispense. You can access a large number of dispensing functions that are useful for day-to-day work in the laboratory.

Large, Interactive Touch Screen

Like a smartphone, the Q-POD® dispenser's interactive touch screen allows you to go anywhere in just a few clicks.

Optimized Lab Space

Protect your working space from clutter! The system is designed for a neat installation and clean lab benches, free of loose tubing and cables. Just interact with your Q-POD® dispenser — the rest of the compact system can easily be integrated in the lab environment. For labs needing more than one ultrapure water point-of-use, up to four Q-POD® dispensers can be connected.

Superior Ultrapure Water — Consistently — to the Trace Level

The Milli-Q® IQ 7000 system provides superior ultrapure water consistently to the trace level with the combination of Jetpore® and IQnano™ resin. Plus, tailored media optimizes performance as purification cartridges can be adapted to your feed water situation, whether extra hard tap water, or Elix® or non-Elix® pure water feed. You can fully rely on the system's water purity for your critical experiments. And with the A10® TOC on-board monitoring, you're spared from uncertainty or misinterpreting results — and also from having to repeat time-consuming and costly analyses.

Water Specifications / International Conformity

Feed water requirements

Feed water quality Pretreated water using EDI, DI, RO or distillation technologies

Conductivity at 25 °C < 100 µS/cm (as NaCl)

Total Organic Carbon (TOC) < 50 ppb

Pressure range* Max 6 bar

Temperature 5 – 35 °C / 41 – 95 °F

* For pressures between 0 and 0.1 bar, the system will operate, but product flow rate may be lower.

Ultrapure, Type 1 water specifications1 (from Q-POD® dispenser)

Resistivity at 25 °C2 18. 2 MΩ·cm

TOC3 ≤ 2 ppb (μg/L)(3), typically ≤ 5 ppb (μg/L)

Particles4 No particles with size > 0.22 µm

Bacteria <0.01 cfu/mL (<10 cfu/L)(4,5)
<0.005 cfu/mL (<5 cfu/L)(6)
Pyrogens (endotoxins)5 < 0.001 EU/mL

RNases5 < 1 pg/mL

DNases5 < 5 pg/mL

Proteases5 < 0.15 µg/mL

Flow rate 0.05 – 2 L/min

1 These values are typical and may vary depending on the nature and concentration of contaminants in the feed water.
2 Resistivity can also be displayed non-temperature-compensated as required by USP.
3 In the appropriate operating conditions, otherwise typically ≤ 5ppb.
4 With Millipak® and Millipak® Gold
5 With Biopak®
6 With Millipak® Gold installed and used in a laminar flow hood

Location

3915 Beryl Road, Suite#130

Raleigh, NC 27607

United States

Hours

Monday — Friday
    8:00am-6pm (EST)
                         Saturday 
                           8:00am-12:00pm (EST)

Contact

contact@rtpscientificsupply.com

                            O:  919-386-0144

M: -304-777-6776